Shop
Showing 601–630 of 1386 results
-
Network Analyzer
HP-Agilent/Keysight 8757C
Features:
76 dB dynamic range
Accurate swept power measurements
40 dB directivity bridges
40 GHz in coax, 110 GHz in waveguide
Buffered plotter/printer output
External disk and internal register save/recall
Limit testing built in
Precision color display
DatasheetSKU: 521 -
Network Analyzer
HP-Agilent/Keysight 8757D CRT
The HP 8757D scalar network analyzer allows you to measure insertion loss, gain, return loss, SWR, and power quickly and accurately . With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance.
Setup time is reduced by external disk save/recall, and measurement data can be sent directly to a printer while you proceed to the next measurement.
You can configure your system using a Keysight PSG signal generator with ramp sweep capability. The dynamic range can be extended from 75 dB to 83 dB using the PSG's high power option.
The Agilent 8757D has four independent display channels that process the signals from the Agilent 85037 series precision detectors, 85025 and 85026 detectors, and the 85027 series directional bridges for logarithmic display, in single channel or ratio mode. Three (optionally four) detector inputs are provided.
The number of points (horizontal resolution) that can be selected depends on the number of traces displayed.
A display is considered faulty if:
• A complete row or column of “stuck” or “dark” pixels.
• More than six “stuck on” pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications.
• More than twelve “dark” pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications.
• Two or more consecutive “stuck on” pixels or three or more consecutive “dark” pixel (but no more than one set of two consecutive dark pixels) “Stuck on” of “dark” pixels less than 6.5 mm apart (excluding consecutive pixels.All analyzer display channels can display any one of the detector inputs or any ratio combination of detector inputs.
Log magnitude >
dBm: single channel power measurement
dB: relative power measurement (ratio or relative to trace memory)SWR > Relative measurements (normalized or ratio measurements) can be displayed in SWR. Channels 1 and 2 only: 401 points or fewer
AUX voltage > The rear panel BNC input ADC IN can be measured and displayed in volts (–10 to +10 volts). Typical maximum error is 60 mV.
Up to 8 operator-selectable colors are available for LCD attributes, such as the grid, measurement traces, and labels.
The minimum sweep time depends on the number of traces displayed and the number of points selected.
Traces are stored and normalized with the highest resolution, independent of display scale/division or offset. With adaptive normalization on the Agilent 8757D, calibration data is interpolated when the frequency span is decreased.
Key Features & SpecificationsUp to 83 dB dynamic range
Buffered plotter/printer output
Built-in limit testing for quick pass/fail decisions
External disc and internal register save/recall of test setups
Color display
Optional internal power meter calibrator and precision detectors provide near power meter accuracy
DISLPAY CRT
Four display channels
Three detector inputs
+16 to –60 dBm dynamic range
AC/DC detection modes
101 to 1601 measurement points/trace
Compatible with the Agilent 85025 and 85026 series detectors and the Agilent 85027 series directional bridges
Limit line testing (channels 1 and 2)
Adaptive normalization
Cursor search functions (max, min, n dB, BW)SKU: 69 -
Network Analyzer
HP-Agilent/Keysight 8757D LCD
The HP 8757D LCD COLOR DISPLAY scalar network analyzer allows you to measure insertion loss, gain, return loss, SWR, and power quickly and accurately . With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance.
Setup time is reduced by external disk save/recall, and measurement data can be sent directly to a printer while you proceed to the next measurement.
You can configure your system using a Keysight PSG signal generator with ramp sweep capability. The dynamic range can be extended from 75 dB to 83 dB using the PSG's high power option.
The Agilent 8757D has four independent display channels that process the signals from the Agilent 85037 series precision detectors, 85025 and 85026 detectors, and the 85027 series directional bridges for logarithmic display, in single channel or ratio mode. Three (optionally four) detector inputs are provided.
The number of points (horizontal resolution) that can be selected depends on the number of traces displayed.
A display is considered faulty if:
• A complete row or column of “stuck” or “dark” pixels.
• More than six “stuck on” pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications.
• More than twelve “dark” pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications.
• Two or more consecutive “stuck on” pixels or three or more consecutive “dark” pixel (but no more than one set of two consecutive dark pixels) “Stuck on” of “dark” pixels less than 6.5 mm apart (excluding consecutive pixels.All analyzer display channels can display any one of the detector inputs or any ratio combination of detector inputs.
Log magnitude >
dBm: single channel power measurement
dB: relative power measurement (ratio or relative to trace memory)SWR > Relative measurements (normalized or ratio measurements) can be displayed in SWR. Channels 1 and 2 only: 401 points or fewer
AUX voltage > The rear panel BNC input ADC IN can be measured and displayed in volts (–10 to +10 volts). Typical maximum error is 60 mV.
Up to 8 operator-selectable colors are available for LCD attributes, such as the grid, measurement traces, and labels.
The minimum sweep time depends on the number of traces displayed and the number of points selected.
Traces are stored and normalized with the highest resolution, independent of display scale/division or offset. With adaptive normalization on the Agilent 8757D, calibration data is interpolated when the frequency span is decreased.
Key Features & SpecificationsUp to 83 dB dynamic range
Buffered plotter/printer output
Built-in limit testing for quick pass/fail decisions
External disc and internal register save/recall of test setups
Color display
Optional internal power meter calibrator and precision detectors provide near power meter accuracy
DISLPAY CRT
Four display channels
Three detector inputs
+16 to –60 dBm dynamic range
AC/DC detection modes
101 to 1601 measurement points/trace
Compatible with the Agilent 85025 and 85026 series detectors and the Agilent 85027 series directional bridges
Limit line testing (channels 1 and 2)
Adaptive normalization
Cursor search functions (max, min, n dB, BW)SKU: 69-1 -
Scalar Network Analyzer
HP-Agilent/Keysight 8757E
The Keysight 8757E scalar network analyzer measures insertion loss, gain, return loss, SWR, and power quickly and accurately. With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance. The Keysight 8757E features three detector inputs and two independent display channels, allowing simultaneous ratioed or non-ratioed measurement of your device's transmission and reflection characteristics. – 75 dB dynamic range – 50 GHz in coax, 110 GHz in waveguide – Optional internal power meter calibrator and precision detectors provide near-power-meter accuracy
SKU: 910 -
Noise Figure Meter
HP-Agilent/Keysight 8970A
Agilent HP 8970A Noise Figure Meter. Features and specifications of the HP 8970A include:
– Frequency Range: 10 MHz to 1600 MHz
– Noise Figure Measurement Range: 0 to 30 dB
– NF Instrumentation Uncertainty: +0.1 dB
– Gain Measurement Range: -20 to+40 dB
– Gain Instrumentation Uncertainty: +0.15 dB
– Input SWR reference impedence: <1.7 10 MHz to 1600 MHz
– Requires 346A/B/C noise source .
DatasheetSKU: n/a -
Noise Figure Meter
HP-Agilent/Keysight 8970B
Il misuratore di rumore Keysight 8970B elimina il mistero dalle misurazioni di figure di disturbo, rendendole facili, precise e ripetibili.
L' HP 8970B può essere utilizzato con le fonti di rumore della famiglia 346 o 347.
La bassa incertezza dello strumento e la correzione automatica del secondo stadio consentono di effettuare letture accurate della cifra di rumore, anche per dispositivi a basso guadagno. Lo strumento dispone di speciali modalità di misurazione per la misurazione del mixer ed è in grado di controllare gli oscillatori locali esterni e il set di test della cifra di rumore 8971C.SKU: 152€900.00 View Product -
Power Supply
HP-Agilent/Keysight E3610A
Agilent basic DC power supplies offer essential features for a tight budget. The single output, 30-60 W, E3610A-E3617A provide small, compact size for bench use- low-noise and excellent regulation- and dual-range outputs (E3610A/11A/12A). The Agilent 30W, single output E3610A is a reliable and convenient power for benchtop use, and offers solid performance and a variety of basic and enhanced capabilities. Output Ratings (Maximum current is derated 1% per °C between 40° to 55°C) – Range 1: 0 to 8 V, 0 to 3 A – Range 2: 0 to 15 V, 0 to 2 A – Power (max): 30 W Ripple & Noise from 20 Hz to 20 MHz – Voltage rms: 200 µV – Peak-to-Peak: 2 mV Load & Line Regulation – 0.01% + 2 mV Meter Resolution – Voltage: 10 mV – Current: 10 mA
SKU: 800
-
Network Analyzer
HP-Agilent/Keysight 8757C
Features:
76 dB dynamic range
Accurate swept power measurements
40 dB directivity bridges
40 GHz in coax, 110 GHz in waveguide
Buffered plotter/printer output
External disk and internal register save/recall
Limit testing built in
Precision color display
Datasheet -
Network Analyzer
HP-Agilent/Keysight 8757D CRT
The HP 8757D scalar network analyzer allows you to measure insertion loss, gain, return loss, SWR, and power quickly and accurately . With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance.
Setup time is reduced by external disk save/recall, and measurement data can be sent directly to a printer while you proceed to the next measurement.
You can configure your system using a Keysight PSG signal generator with ramp sweep capability. The dynamic range can be extended from 75 dB to 83 dB using the PSG's high power option.
The Agilent 8757D has four independent display channels that process the signals from the Agilent 85037 series precision detectors, 85025 and 85026 detectors, and the 85027 series directional bridges for logarithmic display, in single channel or ratio mode. Three (optionally four) detector inputs are provided.
The number of points (horizontal resolution) that can be selected depends on the number of traces displayed.
A display is considered faulty if:
• A complete row or column of “stuck” or “dark” pixels.
• More than six “stuck on” pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications.
• More than twelve “dark” pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications.
• Two or more consecutive “stuck on” pixels or three or more consecutive “dark” pixel (but no more than one set of two consecutive dark pixels) “Stuck on” of “dark” pixels less than 6.5 mm apart (excluding consecutive pixels.All analyzer display channels can display any one of the detector inputs or any ratio combination of detector inputs.
Log magnitude >
dBm: single channel power measurement
dB: relative power measurement (ratio or relative to trace memory)SWR > Relative measurements (normalized or ratio measurements) can be displayed in SWR. Channels 1 and 2 only: 401 points or fewer
AUX voltage > The rear panel BNC input ADC IN can be measured and displayed in volts (–10 to +10 volts). Typical maximum error is 60 mV.
Up to 8 operator-selectable colors are available for LCD attributes, such as the grid, measurement traces, and labels.
The minimum sweep time depends on the number of traces displayed and the number of points selected.
Traces are stored and normalized with the highest resolution, independent of display scale/division or offset. With adaptive normalization on the Agilent 8757D, calibration data is interpolated when the frequency span is decreased.
Key Features & SpecificationsUp to 83 dB dynamic range
Buffered plotter/printer output
Built-in limit testing for quick pass/fail decisions
External disc and internal register save/recall of test setups
Color display
Optional internal power meter calibrator and precision detectors provide near power meter accuracy
DISLPAY CRT
Four display channels
Three detector inputs
+16 to –60 dBm dynamic range
AC/DC detection modes
101 to 1601 measurement points/trace
Compatible with the Agilent 85025 and 85026 series detectors and the Agilent 85027 series directional bridges
Limit line testing (channels 1 and 2)
Adaptive normalization
Cursor search functions (max, min, n dB, BW) -
Network Analyzer
HP-Agilent/Keysight 8757D LCD
The HP 8757D LCD COLOR DISPLAY scalar network analyzer allows you to measure insertion loss, gain, return loss, SWR, and power quickly and accurately . With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance.
Setup time is reduced by external disk save/recall, and measurement data can be sent directly to a printer while you proceed to the next measurement.
You can configure your system using a Keysight PSG signal generator with ramp sweep capability. The dynamic range can be extended from 75 dB to 83 dB using the PSG's high power option.
The Agilent 8757D has four independent display channels that process the signals from the Agilent 85037 series precision detectors, 85025 and 85026 detectors, and the 85027 series directional bridges for logarithmic display, in single channel or ratio mode. Three (optionally four) detector inputs are provided.
The number of points (horizontal resolution) that can be selected depends on the number of traces displayed.
A display is considered faulty if:
• A complete row or column of “stuck” or “dark” pixels.
• More than six “stuck on” pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications.
• More than twelve “dark” pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications.
• Two or more consecutive “stuck on” pixels or three or more consecutive “dark” pixel (but no more than one set of two consecutive dark pixels) “Stuck on” of “dark” pixels less than 6.5 mm apart (excluding consecutive pixels.All analyzer display channels can display any one of the detector inputs or any ratio combination of detector inputs.
Log magnitude >
dBm: single channel power measurement
dB: relative power measurement (ratio or relative to trace memory)SWR > Relative measurements (normalized or ratio measurements) can be displayed in SWR. Channels 1 and 2 only: 401 points or fewer
AUX voltage > The rear panel BNC input ADC IN can be measured and displayed in volts (–10 to +10 volts). Typical maximum error is 60 mV.
Up to 8 operator-selectable colors are available for LCD attributes, such as the grid, measurement traces, and labels.
The minimum sweep time depends on the number of traces displayed and the number of points selected.
Traces are stored and normalized with the highest resolution, independent of display scale/division or offset. With adaptive normalization on the Agilent 8757D, calibration data is interpolated when the frequency span is decreased.
Key Features & SpecificationsUp to 83 dB dynamic range
Buffered plotter/printer output
Built-in limit testing for quick pass/fail decisions
External disc and internal register save/recall of test setups
Color display
Optional internal power meter calibrator and precision detectors provide near power meter accuracy
DISLPAY CRT
Four display channels
Three detector inputs
+16 to –60 dBm dynamic range
AC/DC detection modes
101 to 1601 measurement points/trace
Compatible with the Agilent 85025 and 85026 series detectors and the Agilent 85027 series directional bridges
Limit line testing (channels 1 and 2)
Adaptive normalization
Cursor search functions (max, min, n dB, BW) -
Scalar Network Analyzer
HP-Agilent/Keysight 8757E
The Keysight 8757E scalar network analyzer measures insertion loss, gain, return loss, SWR, and power quickly and accurately. With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance. The Keysight 8757E features three detector inputs and two independent display channels, allowing simultaneous ratioed or non-ratioed measurement of your device's transmission and reflection characteristics. – 75 dB dynamic range – 50 GHz in coax, 110 GHz in waveguide – Optional internal power meter calibrator and precision detectors provide near-power-meter accuracy
-
Noise Figure Meter
HP-Agilent/Keysight 8970A
Agilent HP 8970A Noise Figure Meter. Features and specifications of the HP 8970A include:
– Frequency Range: 10 MHz to 1600 MHz
– Noise Figure Measurement Range: 0 to 30 dB
– NF Instrumentation Uncertainty: +0.1 dB
– Gain Measurement Range: -20 to+40 dB
– Gain Instrumentation Uncertainty: +0.15 dB
– Input SWR reference impedence: <1.7 10 MHz to 1600 MHz
– Requires 346A/B/C noise source .
Datasheet -
Noise Figure Meter
HP-Agilent/Keysight 8970B
Il misuratore di rumore Keysight 8970B elimina il mistero dalle misurazioni di figure di disturbo, rendendole facili, precise e ripetibili.
L' HP 8970B può essere utilizzato con le fonti di rumore della famiglia 346 o 347.
La bassa incertezza dello strumento e la correzione automatica del secondo stadio consentono di effettuare letture accurate della cifra di rumore, anche per dispositivi a basso guadagno. Lo strumento dispone di speciali modalità di misurazione per la misurazione del mixer ed è in grado di controllare gli oscillatori locali esterni e il set di test della cifra di rumore 8971C. -
Power Supply
HP-Agilent/Keysight E3610A
Agilent basic DC power supplies offer essential features for a tight budget. The single output, 30-60 W, E3610A-E3617A provide small, compact size for bench use- low-noise and excellent regulation- and dual-range outputs (E3610A/11A/12A). The Agilent 30W, single output E3610A is a reliable and convenient power for benchtop use, and offers solid performance and a variety of basic and enhanced capabilities. Output Ratings (Maximum current is derated 1% per °C between 40° to 55°C) – Range 1: 0 to 8 V, 0 to 3 A – Range 2: 0 to 15 V, 0 to 2 A – Power (max): 30 W Ripple & Noise from 20 Hz to 20 MHz – Voltage rms: 200 µV – Peak-to-Peak: 2 mV Load & Line Regulation – 0.01% + 2 mV Meter Resolution – Voltage: 10 mV – Current: 10 mA
-
Network Analyzer
HP-Agilent/Keysight 8757C
Features:
76 dB dynamic range
Accurate swept power measurements
40 dB directivity bridges
40 GHz in coax, 110 GHz in waveguide
Buffered plotter/printer output
External disk and internal register save/recall
Limit testing built in
Precision color display
Datasheet -
Network Analyzer
HP-Agilent/Keysight 8757D CRT
The HP 8757D scalar network analyzer allows you to measure insertion loss, gain, return loss, SWR, and power quickly and accurately . With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance.
Setup time is reduced by external disk save/recall, and measurement data can be sent directly to a printer while you proceed to the next measurement.
You can configure your system using a Keysight PSG signal generator with ramp sweep capability. The dynamic range can be extended from 75 dB to 83 dB using the PSG's high power option.
The Agilent 8757D has four independent display channels that process the signals from the Agilent 85037 series precision detectors, 85025 and 85026 detectors, and the 85027 series directional bridges for logarithmic display, in single channel or ratio mode. Three (optionally four) detector inputs are provided.
The number of points (horizontal resolution) that can be selected depends on the number of traces displayed.
A display is considered faulty if:
• A complete row or column of “stuck” or “dark” pixels.
• More than six “stuck on” pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications.
• More than twelve “dark” pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications.
• Two or more consecutive “stuck on” pixels or three or more consecutive “dark” pixel (but no more than one set of two consecutive dark pixels) “Stuck on” of “dark” pixels less than 6.5 mm apart (excluding consecutive pixels.All analyzer display channels can display any one of the detector inputs or any ratio combination of detector inputs.
Log magnitude >
dBm: single channel power measurement
dB: relative power measurement (ratio or relative to trace memory)SWR > Relative measurements (normalized or ratio measurements) can be displayed in SWR. Channels 1 and 2 only: 401 points or fewer
AUX voltage > The rear panel BNC input ADC IN can be measured and displayed in volts (–10 to +10 volts). Typical maximum error is 60 mV.
Up to 8 operator-selectable colors are available for LCD attributes, such as the grid, measurement traces, and labels.
The minimum sweep time depends on the number of traces displayed and the number of points selected.
Traces are stored and normalized with the highest resolution, independent of display scale/division or offset. With adaptive normalization on the Agilent 8757D, calibration data is interpolated when the frequency span is decreased.
Key Features & SpecificationsUp to 83 dB dynamic range
Buffered plotter/printer output
Built-in limit testing for quick pass/fail decisions
External disc and internal register save/recall of test setups
Color display
Optional internal power meter calibrator and precision detectors provide near power meter accuracy
DISLPAY CRT
Four display channels
Three detector inputs
+16 to –60 dBm dynamic range
AC/DC detection modes
101 to 1601 measurement points/trace
Compatible with the Agilent 85025 and 85026 series detectors and the Agilent 85027 series directional bridges
Limit line testing (channels 1 and 2)
Adaptive normalization
Cursor search functions (max, min, n dB, BW) -
Network Analyzer
HP-Agilent/Keysight 8757D LCD
The HP 8757D LCD COLOR DISPLAY scalar network analyzer allows you to measure insertion loss, gain, return loss, SWR, and power quickly and accurately . With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance.
Setup time is reduced by external disk save/recall, and measurement data can be sent directly to a printer while you proceed to the next measurement.
You can configure your system using a Keysight PSG signal generator with ramp sweep capability. The dynamic range can be extended from 75 dB to 83 dB using the PSG's high power option.
The Agilent 8757D has four independent display channels that process the signals from the Agilent 85037 series precision detectors, 85025 and 85026 detectors, and the 85027 series directional bridges for logarithmic display, in single channel or ratio mode. Three (optionally four) detector inputs are provided.
The number of points (horizontal resolution) that can be selected depends on the number of traces displayed.
A display is considered faulty if:
• A complete row or column of “stuck” or “dark” pixels.
• More than six “stuck on” pixels (but not more than three green) or more than 0.002% of the total pixels are within the LCD specifications.
• More than twelve “dark” pixels (but no more than seven of the same color) or more than 0.004% of the total pixels are within the LCD specifications.
• Two or more consecutive “stuck on” pixels or three or more consecutive “dark” pixel (but no more than one set of two consecutive dark pixels) “Stuck on” of “dark” pixels less than 6.5 mm apart (excluding consecutive pixels.All analyzer display channels can display any one of the detector inputs or any ratio combination of detector inputs.
Log magnitude >
dBm: single channel power measurement
dB: relative power measurement (ratio or relative to trace memory)SWR > Relative measurements (normalized or ratio measurements) can be displayed in SWR. Channels 1 and 2 only: 401 points or fewer
AUX voltage > The rear panel BNC input ADC IN can be measured and displayed in volts (–10 to +10 volts). Typical maximum error is 60 mV.
Up to 8 operator-selectable colors are available for LCD attributes, such as the grid, measurement traces, and labels.
The minimum sweep time depends on the number of traces displayed and the number of points selected.
Traces are stored and normalized with the highest resolution, independent of display scale/division or offset. With adaptive normalization on the Agilent 8757D, calibration data is interpolated when the frequency span is decreased.
Key Features & SpecificationsUp to 83 dB dynamic range
Buffered plotter/printer output
Built-in limit testing for quick pass/fail decisions
External disc and internal register save/recall of test setups
Color display
Optional internal power meter calibrator and precision detectors provide near power meter accuracy
DISLPAY CRT
Four display channels
Three detector inputs
+16 to –60 dBm dynamic range
AC/DC detection modes
101 to 1601 measurement points/trace
Compatible with the Agilent 85025 and 85026 series detectors and the Agilent 85027 series directional bridges
Limit line testing (channels 1 and 2)
Adaptive normalization
Cursor search functions (max, min, n dB, BW) -
Scalar Network Analyzer
HP-Agilent/Keysight 8757E
The Keysight 8757E scalar network analyzer measures insertion loss, gain, return loss, SWR, and power quickly and accurately. With high-performance detectors and directional bridges, and a companion Keysight source and printer, this analyzer becomes the basis of a complete measurement system with superb performance. The Keysight 8757E features three detector inputs and two independent display channels, allowing simultaneous ratioed or non-ratioed measurement of your device's transmission and reflection characteristics. – 75 dB dynamic range – 50 GHz in coax, 110 GHz in waveguide – Optional internal power meter calibrator and precision detectors provide near-power-meter accuracy
-
Noise Figure Meter
HP-Agilent/Keysight 8970A
Agilent HP 8970A Noise Figure Meter. Features and specifications of the HP 8970A include:
– Frequency Range: 10 MHz to 1600 MHz
– Noise Figure Measurement Range: 0 to 30 dB
– NF Instrumentation Uncertainty: +0.1 dB
– Gain Measurement Range: -20 to+40 dB
– Gain Instrumentation Uncertainty: +0.15 dB
– Input SWR reference impedence: <1.7 10 MHz to 1600 MHz
– Requires 346A/B/C noise source .
Datasheet -
Noise Figure Meter
HP-Agilent/Keysight 8970B
Il misuratore di rumore Keysight 8970B elimina il mistero dalle misurazioni di figure di disturbo, rendendole facili, precise e ripetibili.
L' HP 8970B può essere utilizzato con le fonti di rumore della famiglia 346 o 347.
La bassa incertezza dello strumento e la correzione automatica del secondo stadio consentono di effettuare letture accurate della cifra di rumore, anche per dispositivi a basso guadagno. Lo strumento dispone di speciali modalità di misurazione per la misurazione del mixer ed è in grado di controllare gli oscillatori locali esterni e il set di test della cifra di rumore 8971C.€900.00 View Product -
Power Supply
HP-Agilent/Keysight E3610A
Agilent basic DC power supplies offer essential features for a tight budget. The single output, 30-60 W, E3610A-E3617A provide small, compact size for bench use- low-noise and excellent regulation- and dual-range outputs (E3610A/11A/12A). The Agilent 30W, single output E3610A is a reliable and convenient power for benchtop use, and offers solid performance and a variety of basic and enhanced capabilities. Output Ratings (Maximum current is derated 1% per °C between 40° to 55°C) – Range 1: 0 to 8 V, 0 to 3 A – Range 2: 0 to 15 V, 0 to 2 A – Power (max): 30 W Ripple & Noise from 20 Hz to 20 MHz – Voltage rms: 200 µV – Peak-to-Peak: 2 mV Load & Line Regulation – 0.01% + 2 mV Meter Resolution – Voltage: 10 mV – Current: 10 mA